Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 13 de 13
Filter
1.
Chinese Science Bulletin-Chinese ; 67(16):1783-1795, 2022.
Article in English | Web of Science | ID: covidwho-2307753

ABSTRACT

In response to the construction process of Healthy China. it is rather important to create a safe, healthy and energy-efficient indoor environment for public buildings. The public building space is often densely populated, with a large flow of people and many types of air pollution, which presents non-uniform dynamic distribution characteristics. This brings great challenges to the control of indoor air safety, especially during the pandemic period of COVID-19. Excessive ventilation may not only cause large energy waste. but also lead to cross-contamination and even a cluster of infection. In this paper, an operation and maintenance (O&M) control system for indoor air safety is developed based on the core concepts and basic methods of human ergonomics. In this system, one of the important human environmental variables is focused for control, i.e.. indoor air pollution level. Especially after the outbreak of COVID-19. droplets and droplet nuclei from respiration are the most significant air pollution categories required for mitigation. Towards the efficient control of air pollution in large public buildings. it should further take into account the interaction of human, equipment and machines (i.e., ventilation_ air purification and disinfection and intelligent control system) and building environment. Firstly, on the basis of the online monitoring of indoor air pollution concentration and personnel flow, the non-uniform dynamic distribution of indoor pollutants and personnel can be obtained by using the non-uniform and low-dimensional rapid prediction models and computer vision processing. Then, the optimal setting results of ventilation parameters (e.g., ventilation modes, supply air rate. etc.) can be outputted by the environmental control decision system. Finally, based on a combination of monitoring sensors, controllers and actuator hardware equipment (at the location of fans or dampers), the intelligent regulation and control of ventilation system can be realized, aimed at minimizing energy consumption and reducing pollutant concentration and exposure level. Meanwhile, the air purification and disinfection system (especially for the disinfection of virus particles) are operated under the condition of the ventilated environment, which can serve as a powerful auxiliary to the maintenance of indoor air safety. The workflow and effect of the O&M control system are demonstrated by an engineering application case of the front hall in the International Convention and Exhibition Center. The results indicate that the non-uniform and low-dimensional rapid prediction model for pollutant concentration is effective for the ventilation control with the average prediction difference of 11.9%. The implementation of the intelligent ventilation system can reduce the risk of human infection to less than 4%. and its energy-saving ratio for the ventilation can be as high as about 45%. Through optimizing the layout strategies of disinfection devices based on the intelligent ventilation control, the space accessibility of negative oxygen ions can be well accepted, to further increase the removal efficiency of air pollution. The calculated value of space disinfection rate is more than 99%, which can further reduce the risk of infection by 1-2 orders of magnitude. This study can provide an important reference for the promotion and upgrading of O&M control system for indoor air safety.

2.
Int J Environ Res Public Health ; 20(5)2023 02 28.
Article in English | MEDLINE | ID: covidwho-2253939

ABSTRACT

Improving the cleaning and disinfection of high-touch surfaces is one of the core components of reducing healthcare-associated infections. The effectiveness of an enhanced protocol applying UV-C irradiation for terminal room disinfection between two successive patients was evaluated. Twenty high-touch surfaces in different critical areas were sampled according to ISO 14698-1, both immediately pre- and post-cleaning and disinfection standard operating protocol (SOP) and after UV-C disinfection (160 sampling sites in each condition, 480 in total). Dosimeters were applied at the sites to assess the dose emitted. A total of 64.3% (103/160) of the sampling sites tested after SOP were positive, whereas only 17.5% (28/160) were positive after UV-C. According to the national hygienic standards for health-care setting, 9.3% (15/160) resulted in being non-compliant after SOP and only 1.2% (2/160) were non-compliant after UV-C disinfection. Operation theaters was the setting that resulted in being less compliant with the standard limit (≤15 colony-forming unit/24 cm2) after SOP (12%, 14/120 sampling sites) and where the UV-C treatment showed the highest effectiveness (1.6%, 2/120). The addition of UV-C disinfection to the standard cleaning and disinfection procedure had effective results in reducing hygiene failures.


Subject(s)
Cross Infection , Robotics , Humans , Disinfection/methods , Xenon , Hospitals , Ultraviolet Rays
3.
Chinese Journal of Emergency & Critical Care Nursing ; 4(1):61-65, 2023.
Article in English | CINAHL | ID: covidwho-2246862
4.
Am J Infect Control ; 2022 Jun 23.
Article in English | MEDLINE | ID: covidwho-2242899

ABSTRACT

The emerging pathogen Candida auris poses major infection prevention challenges as the organism can remain on surfaces for unknown timeframes and can cause severe illness. These challenges are exacerbated in the health care environment with potential spread to a vulnerable population. This report describes the Columbia Veterans Administration Health Care System's encounter with this significant pathogen beginning in October 2020 during the COVID19 pandemic.

5.
Dental Nursing ; 18(7):358-360, 2022.
Article in English | CINAHL | ID: covidwho-1934644

ABSTRACT

Laura Yates discusses what types of wipes are most effective for surface decontamination in the dental practice. Aims & objectives: To inform readers about the different definitions in decontamination To explain why decontamination wipes have increased in popularity To explain the history and use of alcohol in dental decontamination To inform readers about why alcohol alone should not be used on heavily contaminated surfaces Learning outcomes: Readers will understand what role wipes play in the decontamination process and when they should be used Readers will understand the theory behind the use of alcohol in dental decontamination Readers will understand the different options for cleaning and disinfection of surfaces and be able to explain their choice of materials

6.
Chinese Science Bulletin-Chinese ; 67(16):1783-1795, 2022.
Article in Chinese | Web of Science | ID: covidwho-1928264

ABSTRACT

In response to the construction process of Healthy China. it is rather important to create a safe, healthy and energy-efficient indoor environment for public buildings. The public building space is often densely populated, with a large flow of people and many types of air pollution, which presents non-uniform dynamic distribution characteristics. This brings great challenges to the control of indoor air safety, especially during the pandemic period of COVID-19. Excessive ventilation may not only cause large energy waste. but also lead to cross-contamination and even a cluster of infection. In this paper, an operation and maintenance (O&M) control system for indoor air safety is developed based on the core concepts and basic methods of human ergonomics. In this system, one of the important human environmental variables is focused for control, i.e.. indoor air pollution level. Especially after the outbreak of COVID-19. droplets and droplet nuclei from respiration are the most significant air pollution categories required for mitigation. Towards the efficient control of air pollution in large public buildings. it should further take into account the interaction of human, equipment and machines (i.e., ventilation_ air purification and disinfection and intelligent control system) and building environment. Firstly, on the basis of the online monitoring of indoor air pollution concentration and personnel flow, the non-uniform dynamic distribution of indoor pollutants and personnel can be obtained by using the non-uniform and low-dimensional rapid prediction models and computer vision processing. Then, the optimal setting results of ventilation parameters (e.g., ventilation modes, supply air rate. etc.) can be outputted by the environmental control decision system. Finally, based on a combination of monitoring sensors, controllers and actuator hardware equipment (at the location of fans or dampers), the intelligent regulation and control of ventilation system can be realized, aimed at minimizing energy consumption and reducing pollutant concentration and exposure level. Meanwhile, the air purification and disinfection system (especially for the disinfection of virus particles) are operated under the condition of the ventilated environment, which can serve as a powerful auxiliary to the maintenance of indoor air safety. The workflow and effect of the O&M control system are demonstrated by an engineering application case of the front hall in the International Convention and Exhibition Center. The results indicate that the non-uniform and low-dimensional rapid prediction model for pollutant concentration is effective for the ventilation control with the average prediction difference of 11.9%. The implementation of the intelligent ventilation system can reduce the risk of human infection to less than 4%. and its energy-saving ratio for the ventilation can be as high as about 45%. Through optimizing the layout strategies of disinfection devices based on the intelligent ventilation control, the space accessibility of negative oxygen ions can be well accepted, to further increase the removal efficiency of air pollution. The calculated value of space disinfection rate is more than 99%, which can further reduce the risk of infection by 1-2 orders of magnitude. This study can provide an important reference for the promotion and upgrading of O&M control system for indoor air safety.

7.
AORN Journal ; 116(1):P3-P4, 2022.
Article in English | CINAHL | ID: covidwho-1919228
8.
Dental Nursing ; 18(6):284-285, 2022.
Article in English | CINAHL | ID: covidwho-1912186

ABSTRACT

Kate Scheer discusses how infectious dieseases influence infection control in dentistry.

9.
AORN Journal ; 115(5):P2-P3, 2022.
Article in English | CINAHL | ID: covidwho-1825862
10.
Journal of Aesthetic Nursing ; 11(3):136-138, 2022.
Article in English | CINAHL | ID: covidwho-1811405

ABSTRACT

Dr Martyn King explains the precautions and steps that must be taken to ensure that live demonstrations can be performed safely

11.
Korean J Chem Eng ; 39(4): 954-962, 2022.
Article in English | MEDLINE | ID: covidwho-1681740

ABSTRACT

COVID-19 has drawn great attention on the necessity for establishing pathogen-free indoor air. This paper offers an insight into the potential application of a multi-purpose filter to remove fine particulates and disinfect pathogens using melamine sponge with a copper-organic framework. In-situ growth dip coating method was applied to coat Cu-based coordination polymer particle (Cu-CPP) on melamine sponge (MS). The integration of Cu-CPPs with high crystallinity and highly active surface area (1,318.1 m2/g) enabled Cu-CPP/MS to have an excellent capture rate (99.66%) and an instant disinfection rate of 99.54% for Escherichia coli. Electrostatic attraction seemed to play a crucial role in capturing negative-charged pathogens effectively by positive charges on Cu-CPP arising from unbalanced copper ions in Cu-CPP. Disinfection of pathogens was mainly attributed to catalytically active Cu2+ sites. Organic ligand played an important role in bridging and maintaining Cu2+ ions within the framework. This study highlights the design of a new capture-and-disinfection (CDS) air filter system for pathogens using Cu-CPP/MS. It can be applied as a substitute for conventional high-efficiency particulate air (HEPA) filters. Electronic Supplementary Material: Supplementary material is available for this article at 10.1007/s11814-021-1000-4 and is accessible for authorized users.

12.
Dental Nursing ; 17(12):590-591, 2021.
Article in English | CINAHL | ID: covidwho-1590703

ABSTRACT

A look at how dental nurses can contribute to best infection control practices

13.
Front Public Health ; 8: 486, 2020.
Article in English | MEDLINE | ID: covidwho-803456

ABSTRACT

The recent outbreak of COVID-19 has infected a large number of patients, increasing the importance of adequate disinfection of the hospital environment. We conducted this study to explore environmental virus contamination and the effect of terminal disinfection in the isolation ward of patients with COVID-19. A swab kit was used to sample various surfaces in the isolation and observation wards using the smear method. The samples were immediately sent to the PCR department of the laboratory for nucleic acid detection of COVID-19. We analyzed 31 high-frequency contact sites in three isolation wards of actively sick patients, of which seven were positive (22.58%, 7/31). Positive sites included the transfer window, bed rail, buffer room door handle, toilet door handle, and toilet faucet. All 55 samples taken from the wards of cured patients and the wards after terminal disinfection were negative. Virus contamination in areas frequently touched by patients in the isolation ward was high, so the awareness of correct disinfection must be increased. Use of 1,000-2,000 mg/L chlorine-containing disinfectant in the isolation ward was effective.


Subject(s)
COVID-19 , Viruses, Unclassified , Disinfection , Hospitals , Humans , SARS-CoV-2
SELECTION OF CITATIONS
SEARCH DETAIL